CTMC Eca Minikabel 12xSM G.657.A1 (1x12)
Innendørs (Kan også brukes utendørs)
Euro brannklasse iht. EN 13501-6 Eca
Kan kuttes til ønsket lengde mot kappe/trommel tillegg.
Hydrogen passivated, dispersion unshifted, matched cladding bending loss insensitive single mode fibre 9/125 µm
Full compatible with G.652.D fibre
Optical and geometrical properties exceed ITU-recommendations G.652.D and G.657.A1
IEC-60793-2-50, B-657.A 1
ITU-T G.657.A1
| Product characteristics |
|
| Cable type |
CTMC |
| Fibre type |
Single mode 9/125 |
| Optical fibre standard |
ITU-T G.657.A1 |
| Number of fibers |
12 |
| Number of fibers per optical element |
12 |
| Number of cores |
1 |
|
Optical element |
Loose tube, gel filled |
|
Cable metal free
Stripability optical element |
Yes
> 1000 mm, down to primary coating |
| Strain relief |
Yes |
| Type of strain relief |
Aramid fibre |
| Material outer sheath |
LSZH |
| Colour outer sheath |
Black |
| Outer sheath thickness |
0,25 mm |
| Outer diameter approx. |
4,7 mm |
| Marking |
EUROFIBER- TKF CTMC Eca 12x SM G.657.A1 (1x12) A-DQ(ZN) H 74930 {Batch} [-CE-]{Year} {Length} |
| Application |
|
| Standardization |
EN IEC 60794-2 |
| Test procedures |
EN IEC 60794-1-2 |
| Application |
Inside |
| Blow in |
Yes |
| Euro fire class according to EN 13501-6 |
Eca |
| Mechanical specification |
|
| Tensile load short term (Tm) |
600 N |
| Tensile load Long Term (Tl) |
150 N |
| Min. bending radius during installation |
55 mm |
| Min. bending radius after installation |
45 mm |
| Crush resistance acc. meth.E3A |
1500 N/dm |
| Crush resistance acc. meth.E3B |
350 N/dm |
| Mandrel diameter by Crush meth. E3B |
25 mm |
| Impact strength |
3 J |
| Striking surface radius |
10 mm |
Cable strain by Tm Max. fibre stain at Tm |
0,6% 0,5% |
| Torsion resistance |
1800 °/m |
| Kink resistance |
40 mm |
| Optical specification |
|
| Category according to EN 50173 |
OS2 |
| Max. attenuation @ 1310 nm |
0,38 dB/km |
| Max. attenuation @ 1550 nm |
0,25 dB/km |
| Max. attenuation @ 1625 nm |
0,28 dB/km |
| Bending radius fiber (1 turn acc. to ITU rec.) |
30 mm |
| Environmental specification |
|
|
|
| Installation temperature |
-10/50 °C |
| Transportation and storage temperature |
-30/70 °C |
| Operational temperature range Ta1 - Tb1 |
-30/70 °C |
| Operational temperature range Ta2 - Tb2 |
-40/70 °C |
| TC sample length for TC acc.F1 or F12 |
1000 m |
| Max. attenuation increase during Ta2 - Tb2 |
0,15 dB |
| UV resistant |
Yes |
| Other specification |
|
Halogen free (acc. EN 60754-1/2) Vertical flame progagation (for single cable) |
Yes IEC 60332-1-2 / EN 50265-2-1 |
| Logistical specifications |
|
| Unit |
meter |
| Weight (kg) |
0.022 |
| Default packaging |
H X 4000/200 |