CTMC Eca Minikabel 12xSM G.657.A1 (1x12)
Innendørs (Kan også brukes utendørs)
Euro brannklasse iht. EN 13501-6 Eca
Kan kuttes til ønsket lengde mot kappe/trommel tillegg.
Hydrogen passivated, dispersion unshifted, matched cladding bending loss insensitive single mode fibre 9/125 µm
Full compatible with G.652.D fibre
Optical and geometrical properties exceed ITU-recommendations G.652.D and G.657.A1
IEC-60793-2-50, B-657.A 1
ITU-T G.657.A1
Product characteristics |
|
Cable type |
CTMC |
Fibre type |
Single mode 9/125 |
Optical fibre standard |
ITU-T G.657.A1 |
Number of fibers |
12 |
Number of fibers per optical element |
12 |
Number of cores |
1 |
Optical element |
Loose tube, gel filled |
Cable metal free
Stripability optical element |
Yes
> 1000 mm, down to primary coating |
Strain relief |
Yes |
Type of strain relief |
Aramid fibre |
Material outer sheath |
LSZH |
Colour outer sheath |
Black |
Outer sheath thickness |
0,25 mm |
Outer diameter approx. |
4,7 mm |
Marking |
EUROFIBER- TKF CTMC Eca 12x SM G.657.A1 (1x12) A-DQ(ZN) H 74930 {Batch} [-CE-]{Year} {Length} |
Application |
|
Standardization |
EN IEC 60794-2 |
Test procedures |
EN IEC 60794-1-2 |
Application |
Inside |
Blow in |
Yes |
Euro fire class according to EN 13501-6 |
Eca |
Mechanical specification |
|
Tensile load short term (Tm) |
600 N |
Tensile load Long Term (Tl) |
150 N |
Min. bending radius during installation |
55 mm |
Min. bending radius after installation |
45 mm |
Crush resistance acc. meth.E3A |
1500 N/dm |
Crush resistance acc. meth.E3B |
350 N/dm |
Mandrel diameter by Crush meth. E3B |
25 mm |
Impact strength |
3 J |
Striking surface radius |
10 mm |
Cable strain by Tm Max. fibre stain at Tm |
0,6% 0,5% |
Torsion resistance |
1800 °/m |
Kink resistance |
40 mm |
Optical specification |
|
Category according to EN 50173 |
OS2 |
Max. attenuation @ 1310 nm |
0,38 dB/km |
Max. attenuation @ 1550 nm |
0,25 dB/km |
Max. attenuation @ 1625 nm |
0,28 dB/km |
Bending radius fiber (1 turn acc. to ITU rec.) |
30 mm |
Environmental specification |
|
|
|
Installation temperature |
-10/50 °C |
Transportation and storage temperature |
-30/70 °C |
Operational temperature range Ta1 - Tb1 |
-30/70 °C |
Operational temperature range Ta2 - Tb2 |
-40/70 °C |
TC sample length for TC acc.F1 or F12 |
1000 m |
Max. attenuation increase during Ta2 - Tb2 |
0,15 dB |
UV resistant |
Yes |
Other specification |
|
Halogen free (acc. EN 60754-1/2) Vertical flame progagation (for single cable) |
Yes IEC 60332-1-2 / EN 50265-2-1 |
Logistical specifications |
|
Unit |
meter |
Weight (kg) |
0.022 |
Default packaging |
H X 4000/200 |