LTC ADSS-150 Luftkabel 96xSM G.657.A1 (8x12) 13,7mm
Standardlengde trommel: 4/8/ km
Luftspenn: 150 meter
MOQ: 4km
Lev.bet: EXW Fab
The Loose Tube Cable All Dielectric Self-Supporting (LTC ADSS) is a metalfree aerial distribution cable, with dry waterblocking and
aramid yarns under the outersheath. This cable is to be used under all dielectric circumstances, for example on distribution and high
voltage power lines, railway, tram, trolley bus lines and between buildings. Because of its strong tensile members it is suitable for
aerial applications without using additional strenght members. This cable is designed for spans between approx. 150 and 300 mtrs,
depending on installing and surroundings conditions, with the conditions from the NESC tables as a basis. For further information,
please consult document Sag & Tension Calculations under characteristic ?Specification?.
Product characteristics |
|
Cable type |
ADSS |
Fibre type |
Single mode 9/125 |
Optical fibre standard |
ITU-T G.657.A1 |
Number of fibers |
96 |
Number of fibers per optical element |
12 |
Number of cores |
8 |
Optical element |
Loose tube, gel filled |
Cable metal free |
Yes |
Number of layers |
1 Layer |
Strip method |
1 Rip cord |
Strain relief |
Yes |
Type of strain relief |
Aramid fibre |
Material outer sheath |
HDPE |
Colour outer sheath |
Black |
Outer sheath thickness |
1,2 mm |
Outer diameter approx. |
13,7 mm |
Marking |
ACE - TKF LTC ADSS-150 96x SM G.657.A1 (8x12) A-DQ(ZN)2Y 77676 {Batch} {Year} {Length} |
Application |
|
Standardization |
EN IEC 60794-3-20 |
Test procedures |
EN IEC 60794-1-2 |
Application |
Outside |
Euro fire class according to EN 13501-6 |
Fca |
Mechanical specification |
|
Tensile load short term (Tm) |
9600 N |
Cable strain by Tm |
0,80 % |
Max. fiber strain at Tm |
0,05 % |
Tensile load Long Term (Tl) |
8800 N |
Max. operational tension (MOT) |
8800 N |
Max. allowable tension (MAT) |
13100 N |
Min. bending radius during installation |
275 mm |
Min. bending radius after installation |
205 mm |
Crush resistance acc. meth.E3A |
1500 N/dm |
Impact strength |
5 J |
Torsion resistance |
360 °/m |
Optical specification |
|
Category according to EN 50173 |
OS2 |
Max. attenuation @ 1310 nm |
0,38 dB/km |
Max. attenuation @ 1550 nm |
0,24 dB/km |
Max. attenuation @ 1625 nm |
0,26 dB/km |
Environmental specification |
|
Longitudinal water blocking cable |
Yes |
Longitudinal watertight construction |
Super Absorbing Polymer |
Installation temperature |
-15/55 °C |
Transportation and storage temperature |
-40/70 °C |
Operational temperature range Ta1 - Tb1 |
-40/70 °C |
Max. attenuation increase during Ta1 - Tb1 |
0,05 dB |
Operational temperature range Ta2 - Tb2 |
-40/70 °C |
Max. attenuation increase during Ta2 - Tb2 |
0,15 dB |
UV resistant |
Yes |
Other specification |
|
Halogen free (acc. EN 60754-1/2) |
Yes |
Effective E-modulus |
8,1 GPa |
Effective CTE |
13,9 10^-6/°C |
Cross sectional area |
148 mm² |
Logistical specifications |
|
Unit |
meter |
Weight (kg) |
0.139 |