LTC ADSS-150 Luftkabel 96xSM G.657.A1

LTC ADSS-150 Luftkabel 96xSM G.657.A1
Varenr.
534133
EAN:
7073126011437
Lager
0

Kvantumsrabatt

Loading...

LTC ADSS-150 Luftkabel 96xSM G.657.A1 (8x12) 13,7mm

Standardlengde trommel: 4/8/ km
Luftspenn: 150 meter
MOQ: 4km
Lev.bet: EXW Fab

The Loose Tube Cable All Dielectric Self-Supporting (LTC ADSS) is a metalfree aerial distribution cable, with dry waterblocking and
aramid yarns under the outersheath. This cable is to be used under all dielectric circumstances, for example on distribution and high
voltage power lines, railway, tram, trolley bus lines and between buildings. Because of its strong tensile members it is suitable for
aerial applications without using additional strenght members. This cable is designed for spans between approx. 150 and 300 mtrs,
depending on installing and surroundings conditions, with the conditions from the NESC tables as a basis. For further information,
please consult document Sag & Tension Calculations under characteristic ?Specification?.

Product characteristics  
Cable type ADSS
Fibre type Single mode 9/125
Optical fibre standard ITU-T G.657.A1
Number of fibers 96
Number of fibers per optical element 12
Number of cores 8
Optical element Loose tube, gel filled
Cable metal free Yes
Number of layers 1 Layer
Strip method 1 Rip cord
Strain relief Yes
Type of strain relief Aramid fibre
Material outer sheath HDPE
Colour outer sheath Black
Outer sheath thickness 1,2 mm
Outer diameter approx. 13,7 mm
Marking ACE - TKF LTC ADSS-150 96x SM G.657.A1 (8x12) A-DQ(ZN)2Y 77676 {Batch} {Year} {Length}
Application  
Standardization EN IEC 60794-3-20
Test procedures EN IEC 60794-1-2
Application Outside
Euro fire class according to EN 13501-6 Fca
Mechanical specification  
Tensile load short term (Tm) 9600 N
Cable strain by Tm 0,80 %
Max. fiber strain at Tm 0,05 %
Tensile load Long Term (Tl) 8800 N
Max. operational tension (MOT) 8800 N
Max. allowable tension (MAT) 13100 N
Min. bending radius during installation 275 mm
Min. bending radius after installation 205 mm
Crush resistance acc. meth.E3A 1500 N/dm
Impact strength 5 J
Torsion resistance 360 °/m
Optical specification  
Category according to EN 50173 OS2
Max. attenuation @ 1310 nm 0,38 dB/km
Max. attenuation @ 1550 nm 0,24 dB/km
Max. attenuation @ 1625 nm 0,26 dB/km
Environmental specification  
Longitudinal water blocking cable Yes
Longitudinal watertight construction Super Absorbing Polymer
Installation temperature -15/55 °C
Transportation and storage temperature -40/70 °C
Operational temperature range Ta1 - Tb1 -40/70 °C
Max. attenuation increase during Ta1 - Tb1 0,05 dB
Operational temperature range Ta2 - Tb2 -40/70 °C
Max. attenuation increase during Ta2 - Tb2 0,15 dB
UV resistant Yes
Other specification  
Halogen free (acc. EN 60754-1/2) Yes
Effective E-modulus 8,1 GPa
Effective CTE 13,9 10^-6/°C
Cross sectional area 148 mm²
Logistical specifications  
Unit meter
Weight (kg) 0.139

Dokumenter

Filer